EX EARTHING CLAMP FOR CFIBC BIG BAGS
ATEX CERTIFIED EARTHING CLAMP To unload CFIBC BIG BAGS in ATEX Zone 1/21
The Logic ECS-RF-FIBC system is designed to earth Type C FIBC Big Bags, dissipating the static electricity generated during the transport of potentially explosive powders and continuously verifying via the SIL2 electronics that the resistance to earth is always <10M!2.
By using the Logic CLP-FIBC double earthing clamp, equipped with a contact strip that prevents damage to the gripping points. the system is able to recognise the presence of the big bag and cannot be bypassed when connected to metal devices.
TECHNICAL SPECIFICATIONS
- Control unit installation area: ECS-RF-DIN: electronics in Safe Area
- Temperature range: ECS-RF: ATEX Zone 1/21, Control unit in safe area: -20 °C < Tomb’ +70 °C Control unit ATEX Zone 1/21: -20 °C < Tomb ‘ +40 °C
- Standard cable: 5 m straight for EH i applications
- Optional cable: 5 m coiled for Ex i applications
- Power supply: AC version (ECS-RF-DIN): 230Vac, Um=253 Var,
DC version (ECS-RF-DIN-DC): 10+30Vdc, Um=30 Vdc/ 253 Vdc - Control unit dimensions (L x H x D): Control unit for safe area (ECS-RF-DIN): 162 x 90 H 65 mm Control unit for ATEX Zone 1/21 (ECS-RF): 195 H 195 x 148 mm
CLP-FIBC CLAMP SPECIFICATIONS
- Clamp composition: AISI 304 stainless steel Polyamide isolators
- Clamp connection area: ATEX Zone 0/20
- Operating temperature: -20 °C T, b ‘ +70 °C
- Dimensions (L X H X D): 50 x 33 x 140 mm
- Maximum clamp opening: 15 mm